FUJILOK U-nut

Features
- Fastening function: Demonstrates stable locking function
- Dropout prevention: Prevents premature detachment even if the tightening force is lowered
- Reusability: Fuji bearing lock nuts U-nut may be re-used with very little prevailing torque decline.
- Simple fastening: Easy tightening with no need for skilled techniques or specialized tools
- Simplex parts: It demonstrates a locking effect by itself, making parts management easy and preventing installation errors
- Heat and cold resistance: An all-metal product with excellent resistant to heat and cold
Applicable Markets
- Two-wheeled vehicles
- Marine vessels
- Four-wheeled vehicles
- Electronics
- Plants
- Infrastructure
- Special-equipped vehicles
- Playground equipment
- Machine tools
- Civil engineering
- Farm equipment
- Railways
- Industrial equipment
- Architecture
- Conveyers
- Medical care and welfare
- Consists of 3 basic parts
- No need for a lock washer
Structure & Function

The FUJILOK U-NUT consists of a nut and friction ring (specialized ring).The friction ring is secured to and integrated with the top face of the nut by crimping.

| Steel friction ring | 60° 3-wing ring (up to M6) 90° 2-wing ring (M8 and above) |
|---|---|
| Thread accuracy | JIS6H(JIS Class2),formerly JIS Class2, JIS2B |
| Sizes | M3 – M115 *Pitch: Coarse thread and fine thread W3/16-24 – W2″-4.5 NC#10-24 – NC1″1/2-6 NF#10-32 – NF1″1/2-12 *Other special sizes |
| Shapes | FUJILOK U-NUT Single Chamfer(Type 1), Double Chamfer (Type 2), Thin Type (Type 3), Small Type U-NUT, Flange Type U-NUT, Cap Type U-NUT, Weld Type U-NUT. |
| Materials | SS400 or equivalent, S45C thermal refined or equivalent, SUS304 or equivalent, SCM435 (thermal refined), titanium, SUS316L, brass (BSBM) *Other special materials |
Performance of the prevailing torque and reusability
Prevailing torque is produced by the spring effect when the friction ring touches the bolt threads.

Sample
| M12 × 1.75 SS400 equivalent non-plating | |||
|---|---|---|---|
| Maximum Installation torque | Minimum removal torque | ||
| 1cycle | 10cycle | 1cycle | 10cycle |
| 1.20 | 0.75 | 0.70 | 0.50 |
[N・m]
*Via in-house testing
Even re-used 10 times, the prevailing torque shows only a slight decrease.
Test Condition
| Bolt material | Alloy steel (SCM435) |
|---|---|
| Thread accuracy | ISO6g (JIS6g) |
| Surface treatment | plain (nut and bolt) |
| Lubricant | penetrating lubricant |
This test repeatedly applies amplitude and impact in a direction vertical to the axis of the bolts and nuts that are assembled in a vibration plate in order to examine the reduced axial tension of the fastener and judge the locking performance.
Test Condition
| Sample size | M12×1.75 |
|---|---|
| Material of the sample nut, bolt | SS400 or equivalent |
| Axial tension for fastening | 17,150N{1,750kgf} |

Specification of the Junker Type Thread Loosening Testing Machine
| Frequency | 1,278c.p.m. |
|---|---|
| Excitation stroke | 11mm |
| Impact stroke | 10mm |
| Vibration acceleration of the excitation table | 10G |
| Excitation time | 60 min. |
| Direction of impact | Bolt axial direction |
Test Result

Vertical Axis Vibration Test video
NAS Conforming High Speed Thread Looseness Test (according to National Aerospace Standard NAS3350)
This test repeatedly applies shocks in a direction vertical to the axis of the bolts and nuts that are assembled a vibration barrel in order to examine whether or not loosening occurs and judge the locking performance.
Test Condition
| Sample size | M12×1.75 |
|---|---|
| Material of the sample nut, bolt | SS400 or equivalent |
| Axial tension for fastening | 17,150N{1,750kgf} |
Yield point of Bolt σy:314N/mm²{32kgf/mm²}

Specification of NAS Conforming High Speed Thread Loosening Testing Machine
| Frequency | 1,780 c.p.m. |
|---|---|
| Excitation stroke | 11mm |
| Impact stroke | 19mm |
| Vibration acceleration of the excitation table | 19.5G |
Test Result
| Sample size | Frequency | Vibration time |
|---|---|---|
| FUJILOK U-NUT | 30,000cycles | 16′ 51″ |
| No problem | ||
| Double nut | 4,450cycles | 2′ 30″ |
| Failed | ||
| Ordinary nut + Washer | 1,335cycles | 45 sec. |
| Failed | ||
Vertical Axis Vibration Impact Test video
Test Result

Threaded Fastener Tightening Characteristic Test video
Installation Instructions

1

2

3

4

1

2

3



Explore our product range

Download technical documents and brochures.
Keep up to date with the latest product and technical information from IEC and its international supply partners.